The short version of Chromatogram fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2026-06-11 and is reviewed periodically as new material appears.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
==== Drugs ==== A number of medications have been identified which may cause hypoglycemia, through a variety of ways. Moderate quality evidence implicates the non-steroidal anti-inflammatory drug indomethacin and the anti-malarial quinine. Low quality evidence implicates lithium, used for bipolar disorder. Finally, very low quality evidence implicates a number of hypertension medications including angiotensin converting enzyme inhibitors (also called ACE-inhibitors), angiotensin receptor blockers (also called ARBs), and β-adrenergic blockers (also called beta blockers). Other medications with very low quality evidence include the antibiotics levofloxacin and trimethoprim-sulfamethoxazole, progesterone blocker mifepristone, anti-arrhythmic disopyramide, anti-coagulant heparin, and chemotherapeutic mercaptopurine. If a person without diabetes accidentally takes medications that are traditionally used to treat diabetes, this may also cause hypoglycemia. These medications include insulin, glinides, and sulfonylureas. This may occur through medical errors in a healthcare setting or through pharmacy errors, also called iatrogenic hypoglycemia.
=== Etymology === The etymology of melatonin stems from its skin-lightening properties. As detailed in their publication in the Journal of the American Chemical Society, Lerner and his colleagues proposed the name melatonin, derived from the Greek words melas, meaning 'black' or 'dark', and tonos, meaning 'labour', 'colour' or 'suppress'. This naming convention follows that of serotonin, another agent affecting skin color, discovered in 1948 as a modulator of vascular tone, which influenced its name based on its serum vasoconstrictor effect. Melatonin was thus aptly named to reflect its role in preventing the darkening of the skin, highlighting the intersection of biochemistry and linguistics in scientific discovery.
Tadalafil is used to treat erectile dysfunction, benign prostatic hyperplasia, and pulmonary arterial hypertension. In the United States, tadalafil (as Cialis) is indicated for the treatment of erectile dysfunction and the signs and symptoms of benign prostatic hyperplasia; and (as Adcirca) for the treatment of pulmonary arterial hypertension to improve exercise ability.
Glyceraldehyde-3-phosphate can double up to form larger sugar molecules like glucose and fructose. These molecules are processed, and from them, the still larger sucrose, a disaccharide commonly known as table sugar, is made, though this process takes place outside of the chloroplast, in the cytoplasm. Alternatively, glucose monomers in the chloroplast can be linked together to make starch, which accumulates into the starch grains found in the chloroplast. Under conditions such as high atmospheric CO2 concentrations, these starch grains may grow very large, distorting the grana and thylakoids. The starch granules displace the thylakoids, but leave them intact. Waterlogged roots can also cause starch buildup in the chloroplasts, possibly due to less sucrose being exported out of the chloroplast (or more accurately, the plant cell). This depletes a plant's free phosphate supply, which indirectly stimulates chloroplast starch synthesis. While linked to low photosynthesis rates, the starch grains themselves may not necessarily interfere significantly with the efficiency of photosynthesis, and might simply be a side effect of another photosynthesis-depressing factor.
Sources: en.wikipedia.org
=== Hybrids and sub-cultivars === There are a wide variety of breeds for consumer and commercial use of jalapeño plants. The majority fall under one of four categories: F1 hybrids, where the parent plants have been hand-emasculated and cross-bred to produce uniform offspring with hybrid vigor; cultivars which are F-11 or F-12 hybrids or later generations where a stable unique population has been developed; landraces; and F2 hybrids. F1 hybrids produce the highest and most uniform yields but cost 25 times the cost of open-pollinated seed, leading to only 2% of the farmland dedicated to jalapeño cultivation in the United States being planted with F1 hybrids. F2 hybrids often produce similarly to F1 hybrids; however, some F1 hybrids are produced via recessive male sterility to eliminate the need to hand-pollinate, reducing the cost to produce the hybrid, but producing a 25% reduction in yield in the F2 generation. Some notable F1 hybrids are 'Mitla', 'Perfecto', 'Tula', 'Grande' (a hot jalapeño), 'Sayula', 'Senorita', and 'Torreon', most of them being developed and marketed by Petoseed, a brand of Seminis. Cultivars are researched and created to promote desirable traits. Common traits selected for are resistance to viruses and other pepper-related diseases, milder peppers, early ripening, more attractive fruit in terms of size, wall thickness, and corking, and higher yields.
==== Metabolism and elimination ==== 5α-Reductase is a major enzyme involved in the metabolism of progesterone and is known to be expressed in skin in high amounts. For this reason, it has been suggested that rapid metabolism of progesterone by 5α-reductase could account for the low levels of circulating progesterone produced by transdermal application. Studies of progesterone have reported that when progesterone is administered transdermally, 80% is metabolized in the skin and only 20% is likely to pass the skin barrier. Along these lines, a study of radiolabeled progesterone found that 5β-reduced pregnanediol excretion was 8-fold higher than 5α-reduced allopregnanediol excretion with intravenous progesterone yet allopregnanediol excretion was slightly higher than pregnanediol excretion with transdermal progesterone. The metabolites of progesterone in the skin seem to have no hormonal activity. In addition to 5α-reductase, other enzymes, such as 20α-hydroxysteroid dehydrogenase, metabolize progesterone in the skin. Progesterone and/or its metabolites such as 5α-dihydroprogesterone act as 5α-reductase inhibitors and inhibitors of 3α- and 3β-hydroxysteroid dehydrogenases in the skin. On the other hand, other research has cast doubt on the notion that progesterone is robustly metabolized in the skin. One study reported that transdermal progesterone in an alcohol-based gel produced high levels of circulating progesterone. This suggests that formulation rather than metabolism might be a critical limiting factor for the bioavailability of transdermal progesterone.
== Dietary requirements and sources == The Dietary Reference Intake for tyrosine is usually estimated together with phenylalanine. It varies depending on an estimate method, however the ideal proportion of these two amino acids is considered to be 60:40 (phenylalanine:tyrosine) as a human body has such composition. Tyrosine, which can also be synthesized in the body from phenylalanine, is found in many high-protein food products such as meat, fish, cheese, cottage cheese, milk, yogurt, peanuts, almonds, pumpkin seeds, sesame seeds, soy protein and lima beans. For example, the white of an egg has about 250 mg per egg, while beef, lamb, pork, tuna, salmon, chicken, and turkey contain about 500–1000 mg per 3 ounces (85 g) portion.
The Navier–Stokes equations (named after Claude-Louis Navier and George Gabriel Stokes) are differential equations that describe the force balance at a given point within a fluid. For an incompressible fluid with vector velocity field
Heavy-metal contamination of spirulina supplements has also raised concern. The Chinese State Food and Drug Administration reported that lead, mercury, and arsenic contamination was widespread in spirulina supplements marketed in China. One study reported the presence of lead up to 5.1 ppm in a sample from a commercial supplement. Spirulina doses of 10 to 19 grams per day over several months have been used safely.
Sources: en.wikipedia.org
=== Canada === 99.9% nickel five-cent coins were struck in Canada (the world's largest nickel producer at the time) during non-war years from 1922 to 1981; the metal content made these coins magnetic. During the war years 1942–1945, most or all nickel was removed from Canadian and US coins to save it for making armor. Canada used 99.9% nickel from 1968 in its higher-value coins until 2000.
The journey across the United States began on 15 July 1988. On the journey he slept in bushes beneath the World Trade Center, camped outside Kennedy Airport in a tent, then headed west. On Staten Island he collapsed from heat exhaustion at 105 degrees Fahrenheit. In Utah the temperatures went down to minus 30 Fahrenheit. Carrying a tent and a backpack, with no backup, he walked alone to Niagara Falls, through Ontario in Canada, to Detroit, between the Great Lakes, across the Great Plains, through the Rockies in winter, to Yellowstone National Park, then south to the Grand Canyon, on to Las Vegas, through Death Valley and then snowshoed over the Sierras to reach San Francisco. In Death Valley, down to his last $13, Skinner found $200 in the desert, and he had $1 left when he crossed the Sierras to reach Yosemite Valley. The total distance he walked from New York City to San Francisco, was 4,952 miles (7,969 km). On the journey he visited 70 hospices and appeared on television, radio and in newspapers to encourage support for hospices across the U.S. and Canada. The mayor of San Francisco, Art Agnos, proclaimed 21 March 1989, "Colin Skinner Day," in recognition of the attention he brought to the work of hospices with AIDS patients in the city. Returning to Britain after this walk, he obtained a job as a research assistant in Chemical Pathology at the Middlesex Hospital and went on to obtain a PhD in Molecular Biology at University College London.
Kennedy criticized Biden for his conduct of the withdrawal from Afghanistan, saying, "President Biden chose to withdraw from Afghanistan, but there’s no reason it had to be so chaotic. We all saw it: The panic, the fear, the chaos, the abandonment of equipment, the scrambling to destroy unclassified documents and classified documents, thousands of Americans and our allies trapped behind Taliban lines, no plan for the refugees… I am so sorry that all of our American soldiers who fought so valiantly had to witness what we all saw, and what we saw was stunning incompetence." Kennedy has been hawkish on China, especially when it comes to stopping Chinese companies from breaking American stock market rules. He passed two bills, the Holding Foreign Companies Accountable Act and the Accelerating Holding Foreign Companies Accountable Act, to delist any company that refuses to have its audits inspected by the Public Company Accounting Oversight Board. In October 2023, Kennedy visited China as part of a bipartisan congressional delegation led by Senate Majority Leader Chuck Schumer and met with General Secretary of the Chinese Communist Party Xi Jinping. The delegation also met Director of the Office of the Central Foreign Affairs Commission Wang Yi, Chairman of the Standing Committee of the National People's Congress Zhao Leji, and Shanghai Communist Party Secretary Chen Jining. Kennedy supported sending aid to Ukraine, saying, "This is not just the fight for the people of Ukraine. It's a fight for the people of the United States of America.
=== Disorders involving the immune mechanism === 279 Disorders involving the immune mechanism 279.0 Deficiency of humoral immunity 279.00 Hypogammaglobulinemia unspecified 279.01 Selective IgA immunodeficiency 279.02 Selective IgM immunodeficiency 279.03 Other selective immunoglobulin deficiencies 279.04 Congenital hypogammaglobulinemia 279.05 Immunodeficiency with increased IgM 279.06 Common variable immunodeficiency 279.09 Other deficiency of humoral immunity 279.1 Deficiency of cell-mediated immunity 279.10 Immunodeficiency with predominant t-cell defect unspecified 279.11 DiGeorge syndrome 279.12 Wiskott–Aldrich syndrome 279.13 Nezelof syndrome 279.19 Other deficiency of cell-mediated immunity 279.2 Combined immunity deficiency Severe combined immunodeficiency 279.3 Unspecified immunity deficiency 279.4 Autoimmune disease not elsewhere classified 279.5 Graft-versus-host disease 279.8 Other specified disorders involving the immune mechanism 279.9 Unspecified disorder of immune mechanism
Recent economic growth has led to a considerable increase of new millionaires, including the new entrepreneurs, Colombians with a net worth exceeding US$1 billion. In 2017, however, the National Administrative Department of Statistics (DANE) reported that 26.9% of the population were living below the poverty line, of which 7.4% were in "extreme poverty". The multidimensional poverty rate stands at 17.0 percent of the population. The Government has also been developing a process of financial inclusion within the country's most vulnerable population. The contribution of tourism to GDP was US$5,880.3bn (2.0% of total GDP) in 2016. Tourism generated 556,135 jobs (2.5% of total employment) in 2016. Foreign tourist visits were predicted to have risen from 0.6 million in 2007 to 4 million in 2017.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.